A professional ladder inspection includes a close check of the stiles, rungs, feet, locking mechanisms and markings, followed by a function test and a written record of the result. The inspector then tags the ladder as safe to use, in need of repair, or withdrawn from service.
What Should a Professional Ladder Inspection Include on the Day?
A competent inspector begins with a visual examination of every structural part of the ladder. Stiles are checked for bends, cracks, splits and corrosion, while rungs and steps are tested for looseness, wear and contamination from paint, oil or mud.
The inspector then moves on to the working parts, including feet, hinges, spreader bars and locking claws, plus the rope and pulley on extension ladders. Labels and duty ratings are confirmed too, because a ladder that cannot be identified is hard to trace back to a standard such as EN 131.
| Component | What the inspector looks for | Typical outcome if faulty |
|---|---|---|
| Stiles | Bends, cracks, splits, corrosion, dents | Withdrawn from service |
| Rungs and steps | Looseness, wear, damage, slippery residue | Repair or replace |
| Feet | Worn, missing or damaged rubber or end caps | Replace feet |
| Locking mechanisms | Bent claws, stiff hinges, faulty spreader bars | Repair or withdraw |
| Labels and markings | Legible duty rating, manufacturer details, ID number | Re-label or retire |
Need a Ladder Inspection? Talk with one of our Ladder Inspection professionals today!

Five Things to Check Before Using a Ladder Between Inspections
A professional inspection does not replace a quick look before each climb. A pre-use check takes under a minute, and it catches the damage that appears between formal inspections.
The five checks are the stiles, the rungs, the feet, the locking mechanisms and the ground the ladder will stand on.
If any of them looks wrong, the ladder stays on the ground and the fault gets reported. Using it “just this once” is exactly how most ladder accidents begin.
How to Fill Out a Ladder Inspection Tag After a Professional Inspection
A ladder inspection tag is a simple record attached to the ladder, so it needs enough detail to show who checked it and when. Most tags ask for a unique ladder ID or serial number, the inspection date, the inspector’s name or initials, the result, and the date the next inspection is due.
Write clearly in permanent ink and tick the pass or fail box rather than adding vague comments, so anyone on site can read the status at a glance. A failed ladder should carry a clear out-of-service tag and be removed from use, so nobody picks it up by mistake.
Want a Ladder Inspection? Speak to one of our Ladder Inspection Experts
What Are the Legal Requirements for Inspecting Ladders in the UK?
Under the Work at Height Regulations 2005, employers must make sure equipment used for work at height is suitable, stable and strong enough, and that it is inspected where its safety depends on how it is used. The regulations do not set a fixed inspection frequency for ladders, so the duty is to choose a sensible interval based on risk.
The HSE’s ladder guidance expects regular checks, prompt repair of defects and replacement of damaged equipment, and a written record is widely seen as good practice. The intervals below reflect typical industry practice rather than a legal minimum.
| Usage level | Typical inspection interval | Example setting |
|---|---|---|
| Light, occasional use | Every six months | Office or small premises |
| Moderate, regular use | Every three months | Maintenance teams, retail |
| Heavy, daily use | Monthly | Building trades, utilities |
| After damage or an incident | Immediately | Any workplace |
What a Professional Ladder Inspection Includes: Final Thoughts
A professional ladder inspection is a structured check of every part of the ladder, from the stiles and rungs to the feet, locks and labels. It ends with a clear pass or fail decision and a dated record that proves the work was done.
The law leaves the frequency to the employer’s risk assessment, which means regular documented inspections, backed by quick pre-use checks, are the safest way to show that equipment is being properly managed. A properly completed tag makes that process visible to everyone on site.
Treat the inspection as part of a routine rather than a one-off job, and any ladder that fails should be withdrawn straight away. That habit protects the people using the equipment and the business that is responsible for it.
What Does a Professional Ladder Inspection Include: Frequently Asked Questions
It is a documented examination of a ladder by a competent person who checks its structure, working parts and markings. The ladder is then passed, repaired or withdrawn, and the decision is recorded.
Any competent person with the training and experience to spot defects can do it, whether they work in-house or for an external provider. They should understand the relevant standards and be able to judge when a ladder is no longer safe.
There is no fixed legal interval, so the frequency should follow your risk assessment. Many organisations inspect every three to six months, and monthly for ladders in heavy daily use.
A single ladder usually takes only a few minutes to examine properly. A large fleet takes longer, mainly because of the recording and tagging.
Bent or cracked stiles, loose or damaged rungs, missing feet and faulty locks are the most common reasons. Any defect that affects stability or strength means the ladder should be withdrawn.
Yes, although the parts checked differ slightly. Stepladders need their hinges, spreader bars and platforms checked, while extension ladders also need their ropes, pulleys and locking claws examined.
The Work at Height Regulations 2005 require equipment to be suitable and, where relevant, inspected. The HSE’s safe use of ladders guidance explains what employers are expected to do in practice.
A written record is not always strictly prescribed for ladders, but it is strongly recommended. It gives you clear evidence of who inspected the ladder, when, and what was found.
A tag should show the ladder ID, the inspection date, the inspector’s name, the result and the next due date. Keeping the wording short and legible helps everyone on site understand the status instantly.
You can carry out a sensible visual check before each use, looking at the stiles, rungs, feet and locks. A formal inspection is aimed at workplaces, but the same checks still help to prevent accidents at home.
It should be tagged as out of service and removed from use straight away. It can only return once a competent person has repaired it and confirmed it is safe.
Some parts, such as feet, rubber caps and certain hinges, can be replaced by a competent person. Bent or cracked stiles are usually beyond repair, and the ladder should be retired.
Yes, because each material fails in its own way. Aluminium ladders are checked for dents and corrosion, while timber ladders are checked for splits and rot, and fibreglass ladders for cracks and fibre damage.
Treat it as unsuitable until a competent person can confirm its type, duty rating and condition. Many employers simply retire unidentifiable ladders, because they cannot prove that the equipment is fit for use.